Medium-voltage switchgear suppliers

Medium-voltage switchgear takes the utility or campus feed at 1 to 52 kV and switches it through vacuum breakers to the transformers. This hub lists 38 suppliers. 30 publish a rating of 36 kV or more, and four publish 63 kA: Powell↗, ABB↗, Schneider Electric↗ and IEM↗. Each figure links to the datasheet it came from.

38 suppliersChecked

SF6-free MVStandards and certifications
Daelim Transformer521———IEEE C37.20.2; IEEE C37.20.3; IEC 62271-200 (MV); UL 1558; UL 891; IEC 61439 (LV)China2026-11-11
ABB40.516314,0001Yes—Switzerland2026-11-11
CG Power and Industrial Solutions40.51————India2026-11-11
CHINT40.522521,2502—IEC 62271-200China2026-11-11
Ormazabal40.5131.512,5001—IEC; IEEE (ETL listed); ENASpain2026-11-11
Siemens40.515014,0001—IEC 62271-200; GB3906 (NXAirS)Germany2026-11-11
TAMCO Switchgear40.515013,1501—IEC 62271-100/-200/-102 (VHIH)Malaysia2026-11-11
Vertiv40.524022,5002—UL 891 (US low-voltage switchboard option); IEC 62271 (MV); IEC 61439 (LV)United States2026-11-11
Crown Technical Systems381———IEEE; NEMA; ANSIUnited States2026-11-11
Eaton3814013,0001—IEEE C37.20.2; CSA C22.2 No. 31Ireland2026-11-11
Federal Pacific382—1,2002——United States2026-11-11
G&W Electric3811619001—IEEE C37.74; IEEE C37.60; IEEE 386; IEC 60529United States2026-11-11
HD Hyundai Electric3815014,0001—IEC 62271-200; ANSI/IEEE C37.20.2South Korea2026-11-11
Hyosung Heavy Industries3814014,0001Yes—South Korea2026-11-11
IEM3816324,0002—ANSI/IEEE C37.20.2; C37.55United States2026-11-11
JST Power Equipment3814013,0001Yes—United States2026-11-11
LS Electric381————South Korea2026-11-11
Lucy Electric3822556302YesIEC 62271-1, -100, -102, -103, -105, -200, -206, -213; IEC 60255United Kingdom2026-11-11
Myers Power Products381—4,0001—UL 1558 and UL 891 designs available for LV assembliesUnited States2026-11-11
nVent381————United Kingdom2026-11-11
Powell Industries3816314,0001—ANSI C37.20.2; C37.20.7United States2026-11-11
S&C Electric3822522,0002Yes—United States2026-11-11
Schneider Electric3836314,0001——France2026-11-11
W-Industries3814012,0001—IEEE C37.20.2-2025; UL witness testing completedUnited States2026-11-11
alfanar3614024,0002—IEC 62271-1; IEC 62271-200; IEC 62271-100 (NES-H)Saudi Arabia2026-11-11
Efacec3615014,0001——Portugal2026-11-11
Lauritz Knudsen Electrical & Automation361501———India2026-11-11
Meidensha36131.512,5001—IEC 62271-200Japan2026-11-11
Trystar3614014,0001—ANSI/IEEE C37.20.3 (MV metal-enclosed); UL 891 / UL 1558 (LV)United States2026-11-11
WEG36131.512,5001——Brazil2026-11-11
Cummins271———UL 891 or UL 1558 (LV paralleling switchboards); IEEE C37.20.2 (MV)United States2026-11-11
Fuji Electric2412512,5001—IEC 62271-200 (VC-V20A-1)Japan2026-11-11
GE Vernova17.524024,0002—IEC 62271-200 (M-Tier)United States2026-11-11
Mitsubishi Electric1514014,0001—IEC 62271-200 (MS-E)Japan2026-11-11
Russelectric151———UL 1008A; IEEE, NEMA and ANSI standardsUnited States2026-11-11
COMECA————IEC 61439-1 and -2France2026-11-11
Mission Critical Group————ANSI; IEEE; UL (exact standards depend on assembly); UL 891; UL 1558 (LV); IEEE C37.20.2; C37.20.7; C37.20.9United States2026-11-11
Toshiba————IEC; ANSI (TTDA distribution products)Japan2026-11-11

How to read an MV rating

How ratings are read

Three numbers, three jobs

Voltage (kV) sets the insulation class and decides whether a lineup suits a 12 kV or a 36 kV campus. Busbar current (A) is how much the main bus carries continuously. Short-circuit rating (kA) is what the assembly withstands, or the breaker interrupts, when a fault hits. They are different duties with different test durations, and they rarely peak in the same model.

Family maxima are not one product

The table shows the highest figure each supplier publishes across the families we researched. ABB’s UniGear ZS1 runs to 24 kV and 4,000 A, but its 63 kA rating holds only up to 17.5 kV; its 40.5 kV ZS3.2 is rated 31.5 kA↗. Open a supplier page and read the rating scope before you put two numbers side by side.

Insulation and SF6

Air-insulated metal-clad and metal-enclosed gear is common across the list. Gas-insulated designs shrink the footprint, and the SF6-free options use dry air or a CO2 mixture instead of sulfur hexafluoride.

Need the low-voltage side of the same room? See low-voltage switchgear suppliers, or the US-headquartered makers when UL and ANSI listing is the first filter.